The Door & Environmental Sensor is a smart sensor designed to help Fleet Managers and Fleet Admins monitor their reefer fleet with ease and efficiency. It provides real-time monitoring of door status, temperature, and humidity, enabling fleet managers to stay updated with critical data.
Before you begin
- Install an Asset Gateway Mini (AG-31.3 or newer) or Vehicle Gateway on the reefer first and assign it to the asset. The DES-2 connects through it and can't transmit data on its own.
- Note the DES-2 requires a cable-powered Asset Gateway Mini (AG-31.3 or newer), AG Solar, or Vehicle Gateway.
- Note that the Vehicle Gateway cannot support the Motive Beacon and the Door and Environmental Sensor simultaneously.
- For the most reliable, continuous readings, use a cable-powered Asset Gateway Mini rather than battery-powered because battery mode won't deliver sensor data until external power is restored.
- Identify your door type (swing or roll-up) before choosing a mounting spot. The two door types have different setup methods.
- Have the following tool available that came in the box ready:
- Sensor
- 5 Small Phillips mounting plate screws
- Mounting plate
- Pin
- Alcohol wipe
- Magnet
- 5 Large mounting plate screws
- 3 T6 screws for the device
- Spare adhesive
Activate and pair sensor
- Press and release the pinhole button on the side of the sensor by inserting the pin.
- The LED will blink blue, indicating the sensor is beginning the pairing process.
- Proceed immediately to the positioning instructions for the door type. This blinking behavior is for the first 30 minutes after activation or button press.
Position the sensor for your door type
Roll-up doors:
- Set the magnet aside. It's only used for swing doors.
- Orient the sensor with the LED on the bottom, and place it so it sits vertical when the door is closed and horizontal when the door is open. Attach it to the interior side of the door if possible.
Swing doors:
- For installing on Swing doors, place the magnet on the top edge of the door.
- Place the sensor on the ceiling, oriented so the LED is directly facing the magnet.
- Ensure the sensor and magnet are within the following maximum distances:
- Metal surfaces: 12mm (½ inch apart)
- Other materials: 22mm (⅞ inch apart)
- When the door closes, the sensor blinks green once. When the door opens, it blinks white once.
| Note: This blinking behavior is for the 1st 30 minutes after activation or button press. |
| Note: If the sensor will not fit on the ceiling, you can swap the positions of the sensor and magnet as long as the sensor's LED continues to face the magnet and within maximum distance of the magnet. Proceed to the mounting instructions. |
| Note: The Door & Environmental Sensor can be installed on both a roll-up or swing door on a refrigerated truck. |
Mount the sensor
- Use the included alcohol wipe to clean the area where you want to attach the mounting plate and magnet.
- Remove the adhesive backing from the mounting plate and affix it to your desired location.
- If using the magnet, remove its adhesive backing and affix it to your desired location.
- For metal surfaces, use the small mounting plate screws; for wood surfaces, use the large mounting plate screws.
- Attach the sensor (and magnet, if used) to the mount and secure it using the device screws.
- At least 10 minutes after you first push the pinhole button, quickly press and release the button again.The LED will turn solid blue if your sensor has successfully paired with your Asset Gateway.
| Note: If your Motive Gateway is installing firmware updates, you may need to wait 30-60 minutes before your sensor is successfully paired and data appears in your Fleet App or dashboard. |
Assign the Door & Environmental Sensor to your asset
Using the Fleet App:
-
Log in and go to More > Devices.
-
Tap Install Door and Env. Sensors.
-
Select your sensor from the list, or search by serial number, then tap Continue.
-
Select an asset from the list, then choose the data transmission source (Asset Gateway or Vehicle Gateway).
-
Select Door and Environmental in the Sensor Usage section.
-
Select your Door type.
-
Select the temperature zone for the installation of your Door and Environmental Sensor.
-
Select one of the given Location options for the installation.
-
Tap Assign.
-
Place the Door and Environmental Sensor at the mounting location and tap Next.
- Follow the given instructions to activate the sensor.
- Tap Light flashed blue once the sensor is activated and flashing blue.
-
Sensor data will start refreshing.
- Once refreshed, you can see the Door status, Temperature, and Humidity of the selected Zone.
- Values automatically refresh every minute; tap Refresh data if you want to refresh the values again.
-
Tap Continue to proceed.
- Tap Device mounted once you in the mount sensor section.
-
From the Assignment complete screen, you can go to the Installation guide for next steps, tap Install another sensor, or tap Finish to proceed as you wish.
How to know it worked: The LED turns blue, indicating the sensor is beginning the pairing process with the Asset Gateway and has a good signal.
If it doesn't:
- Still blinking blue: The sensor is still trying to pair with the Vehicle Gateway or Asset Gateway.
- Blinking red: Paired Vehicle Gateway or Asset Gateway cannot be found. This can happen when the Vehicle Gateway or Asset Gateway mini is on battery power.
- Solid yellow: Connectivity to the Vehicle Gateway or Asset Gateway is weak. The sensor is still paired but has a poor signal.
Next steps
- Confirm Door and Environmental Sensor data is populating in the Fleet Dashboard. Fleet Admins can review real-time door status, temperature, and humidity readings in the Fleet Dashboard. See viewing assets with Door & Environmental Sensors on the Fleet Dashboard.
- Drivers can review real-time door status, temperature, and humidity readings in the Fleet Dashboard. See Viewing live reefer data.
Share this with others